+86-21-58588205
Portable Tonometer

Portable Tonometer

SW-500 portable tonometer is based on the principle of dynamic induction. Its core function is to calculate the intraocular pressure value through the deceleration of the magnetized probe after hitting the cornea, combined with the design of the disposable probe, which considers safety and...

Description

SW-500 portable tonometer is based on the principle of dynamic induction. Its core function is to calculate the intraocular pressure value through the deceleration of the magnetized probe after hitting the cornea, combined with the design of the disposable probe, which considers safety and accuracy.

 

Portable tonometer Features:

1. Non-invasive, non-anesthetic, rapid intraocular pressure measurement

Operation process: Install the probe → Close to the eye → Press the button to complete 6 instantaneous measurements (about 0.1 seconds/time→ Automatically display the average value. )

Scope of application: - Human beings (including children, dementia patients, corneal edema or unevenness);

- Animal ophthalmology experiments (e.g. rabbits, pets) without anesthesia.

 

2. Data management and compatibility

- Stores nearly 10 patient data and supports wireless infrared printing

 

3. Wide application scope

Postoperative monitoring: After vitrectomy (inert gas or silicone oil filled eyes), the results are highly consistent with Goldmann tonometry (GAT), solving the problem of difficult measurement with traditional equipment;

Home self-test: Glaucoma patients can use it at home to reduce the cost of screening time.

 

4. Comparison with other types of tonometers

characteristic

Portable tonometer (Rebound type)

Goldmann tonometer

Non-contact Tonometer (NCT)

Anesthesia is required

Without

Epithetis is required

Without

Cornea requirements

Corneal edema/inflatness is still applicable

The cornea is required to be smooth

When the cornea is abnormal, the error is large

Portability

Portable

Slit lamp fixation is required

Desktop

Animal suitability

be

not

not

Postoperative consistency

Highly correlated with GAT (post-vitreous surgery)

The gold standard

The gas filling eye error will be significant

 

Specifications:

1. Portable non contact tonometer

2. Measuring Range :3mmHg~70mmHg

3. Measuring Error: ±1.5mmHg(3mmHg≤intraocular pressure≤25mmHg)

                                        ±2.5mmHg(25mmHg<intraocular pressure≤70mmHg)

4. Measurement can go along both in standing and lying posture

5. Wireless data printing

6. No anesthesia, avoiding discomfort reaction

Hot Tags: portable tonometer, China, suppliers, manufacturers, factory, wholesale, buy, price, cheap, in stock, for sale, Auto Non Contact Tonometer, Goldmann Applanation Tonometer

Contact Supplier